| Ozone PM2.5 PM10 Carbon Monoxide Nitrogen Dioxide Sulfur Dioxide Lead |
Vermont operated two ozone (O3)
monitoring sites in 2003; one at the Proctor Maple Research Facility in
Underhill and the other in Bennington. The 8-hour average ozone National
Ambient Air Quality Standard (NAAQS) is 0.08 parts per million (ppm) and
is assessed relative to the running 3-year average of the annual 4th maximum
daily maximum 8-hour average. Based on this criteria, both Underhill and
Bennington are 100% of the NAAQS (0.08 ppm) for 2003; this is in compliance
with the standard, which must not be exceeded. The highest 8-hour concentration
of ozone in 2003, 0.082 ppm, was recorded at the Bennington site.
The highest recorded 8-hour concentration of ozone at the Proctor Maple Research
site was 0.077 ppm. The highest 1-hour concentration of ozone in 2003,
0.093 ppm, was recorded at the Bennington site while the
highest recorded 1-hour concentration of ozone at the Proctor Maple Research Facility
was 0.085 ppm.
|
|
PM2.5
Vermont maintained four monitoring sites
that sampled for particulate matter with aerodynamic diameter < 2.5
microns (PM2.5). PM2.5 sampling in 2003 was conducted
at Rutland, Bennington Airport Road, Burlington Zampieri Building and Burlington Main Street.
PM2.5 sampling was discontinued in 2003 at both the Bennington Bradford Street site and
at the Proctor Maple Research Facility in Underhill. PM2.5 sampling continues
in Underhill through the IMPROVE program and the Bennington Bradford Street site
was moved to the Bennington Airport Road site.
Vermont began
PM2.5 sampling in 1999. The annual average PM2.5
standard is assessed relative to the three-year average of the respective
annual averages. The PM2.5 annual average NAAQS is 15 micrograms
per cubic meter (µg/m3). Compliance was assessed at only the Burlington
Zampieri site as it was the only site with the last three consecutive years of annual averages.
Both the Bennington Airport Road site and the Burlington Main Street site were established in
2003. Rutland's annual average was not used for compliance assessement due to less than 75%
data capture because the site was taken off-line for the 4th quarter due to local
construction. The three-year average as the Burlington Zampieri site was
9.6 µg/m3 (64% of NAAQS). The PM2.5
24-hour average standard is assessed relative to the three-year average
of the annual 98th percentile sample concentration. Given Vermont's 1-in-3
day sampling schedule, the annual 98th percentile concentration is the
annual third 24-hour maximum concentration. The PM2.5 24-hour
standard is 65 µg/m3. Compliance was assessed at the Burlington Zampieri
site and the three-year 98th percentile
average was 31 µg/m3 (47% of NAAQS).
|
|
PM10
In 2003, Vermont maintained only one monitoring
site that sampled for particulate matter with aerodynamic diameter <
10 microns (PM10) for the entire year at Burlingon Main Street.
The highest 24-hour concentration recorded in Burlington for 2003 was
51 µg/m3. The annual PM10
average (weighted) concentration in Burlington was 19 µg/m3.
These concentrations are well below the former PM10 annual
maximum 24-hour average NAAQS of 150 µg/m3 and the PM10
annual average NAAQS of 50 µg/m3.
Yearly variability in the data is common, in part determined
by meteorology, transport of particulate matter from distant sources,
and changes in the emission strength of local sources.
|
|
Carbon Monoxide
During 2003, Vermont operated two Carbon
Monoxide (CO) sites in Rutland and Burlington Main Street.
No exceedance of the NAAQS for CO was recorded.
The highest 1st and 2nd maximum 8-hour concentrations of CO recorded at
Rutland were 2.2 ppm and 1.9 ppm.
The highest 1st and 2nd maximum 8-hour concentrations of CO recorded at
Burlington were 1.9 ppm and 1.7 ppm. The five-year trend line shows in Rutland shows a slight
downward trend with the second highs at levels between 21% and 28% of the 8-hour NAAQS
of 9 ppm. The Burlington CO site was not in operation in 2002; however
was put back in operation for 2003 where it continues to operate.
CO measured in Burlington from 1995 through
1999 resulted in second 8-hour maximums ranging between 24% and 37% of
the standard. The second 8-hour maximum in Burlington of 1.7 ppm in 2003
was 19% of the standard. In 2003, the maximum one-hour concentration of CO recorded
at Burlington and Rutland was 2.9 ppm and 3.1 ppm, respectively.
|
|
Nitrogen Dioxide
Vermont operated two nitrogen dioxide (NO2)
monitoring sites in Rutland and Burlington Main Street in 2003.
No exceedance of the NAAQS for NO2
was recorded. In 2003,
the annual average for NO2 at
Burlington and Rutland was 0.015 ppm and 0.012 ppm, respectively.
Historical data for the most recent five years (1999-2003)
indicate that the annual average concentrations of NO2 have
remained relatively stable. During this time period, the annual averages
for the Rutland site ranged from 0.011 ppm to 0.013 ppm NO2.
The Burlington NO2 site was not in operation in 2002; however
was put back in operation for 2003 where it continues to operate.
During the period of 1996 to 2000, the
annual average NO2 concentrations ranged from 0.017 ppm to
0.018 ppm in Burlington. The five-year annual NO2 average trend
in Burlington and Rutland ranged between 21% to 34% of the NAAQS. In 2003,
the maximum one-hour concentration of NO2 recorded
at Burlington and Rutland was 0.060 ppm and 0.075 ppm, respectively.
|
|
Sulfur Dioxide
In 2003, Vermont maintained one sulfur dioxide
(SO2) monitoring site in Rutland. No exceedance or violation
of the NAAQS for sulfur dioxide was recorded. The Burlington NO2 site
was not in operation in 2003; however
was put back in operation for 2004. The highest 24-hour average
concentration of SO2 in Rutland in 2003 was 0.029 ppm. The
highest 3-hour and 1-hour average SO2 concentrations were 0.062
and 0.073 ppm, respectively. The annual average of 0.004 ppm in Rutland
for 2003 is 13% of the NAAQS. For compliance purposes, the annual second
maximum 24-hour average of 0.026 ppm is 19% of the NAAQS. The annual second
maximum 3-hour average of 0.050 ppm is 10% of the NAAQS. Five years (1999-2003)
of historical SO2 data indicate little variability in SO2
concentrations in Rutland.
|
|
Lead
Vermont is not required to measure the concentration
of lead in ambient air. No measurement data are available. [Note: The
Vermont Air Pollution Control Division discontinued monitoring lead concentrations
in Vermont in 1989.]
|